Who would benefit from a UPS for a garden office router?

Back up your router only

If you mainly want to keep a single router running through brief power cuts, check its power supply specifications and connection. PowerWalker and Eaton both offer DC UPS solutions for compatible device configurations.

Back up your entire internet setup

If you need to power other devices with their own power supplies as well as your router, check the connections required and the combined load. PowerWalker lists four battery-backed sockets out of eight on the VI 600 MS.

A garden office with fluctuating temperatures

If your UPS will be in an unheated or damp room, its operating conditions must suit the actual location. Manufacturers’ specifications for temperature and humidity vary by model.

What should you look for when choosing one?

DC UPS with a fixed 12 V output

Suitable if: Your single router is confirmed to require 12 V DC, and the connection and power requirements are compatible with the specific model.

Keep in mind: A different voltage or incompatible barrel connector rules out a simple direct connection. Runtime examples are not a guarantee for your load.

DC UPS with selectable output voltage

Suitable if: You know your device’s voltage and connector, and can find an adjustable model to match. Eaton lists selectable 9, 12, 15 or 19 V outputs and four barrel connector adapters for the 3S Mini 3SM36.

Keep in mind: The setting and output capacity must be right for your device. A DC UPS will not automatically power several separate devices with their own power supplies.

Socket-outlet UPS

Suitable if: You want to power your router and other devices together using their existing power supplies.

Keep in mind: According to the manufacturer, four of the eight sockets on the PowerWalker VI 600 MS are battery-backed. Larger plug-in power supplies may also take up space next to each other.

What matters What to check before buying Who should pay particular attention?
Electrical and physical compatibility Check the output voltage, power capacity and connector against the router and power supply specifications. Consumers who want to check that the voltage, power and connector suit their router first may account for around 33% of buyers.
Backup time for your own load Note your required runtime and total load. Compare runtime figures only when they relate to the same stated load. Anyone aiming to keep their own device setup running for a specific time without restarting may be among the consumers who account for around 27% of buyers.
Powering your entire internet setup List every device you need to power. For a socket-outlet UPS, check which outputs are battery-backed and make sure the total load is within its capacity. Consumers who need to account for devices with separate power supplies as well as their router may make up around 20% of buyers.
Suitability of the location Compare the temperature and humidity at the location with the operating conditions specified for the particular model. Anyone who first needs to check whether the UPS can be used in a potentially unheated or damp garden office may be among the roughly 20% of these consumers.

What mistakes should you avoid?

  • Assuming an advertised runtime will apply to your router

    Manufacturers’ examples are based on specific loads, or do not specify the load in detail. An earlier article by heise online also points out that load and backup time do not have a straightforward linear relationship.

    Compare runtime figures only when the load is known, and check your complete planned setup.

  • Counting only the total number of sockets

    According to the manufacturer, four sockets on the PowerWalker VI 600 MS are battery-backed, while the other four offer surge protection only.

    Plug all the power supplies you need into battery-backed outputs, and check that they will fit next to each other.

    A power supply you need may take up another battery-backed socket, or mean you need a UPS with a different configuration.

  • Installing a UPS in your garden office without checking first

    The operating conditions for the specific model must suit its location. Eaton specifies 0 to 35 °C for the 3SM36. For the models covered here, PowerWalker specifies 0 to 40 °C and requires non-condensing humidity conditions.

    Compare the conditions at the actual location, including during unheated periods, with the datasheet for the exact model.

Which brands are worth considering?

PowerWalker / BlueWalker

The range includes a DC solution for compatible 12 V devices, as well as socket-outlet UPSs for other connection setups.

  • The manufacturer provides connection, load and runtime specifications for the DC SecureAdapter 12V.
  • According to the manufacturer, only four of the eight sockets on the VI 600 MS are battery-backed. An earlier review by heise online highlights potential space issues with larger plug-in power supplies.

Eaton

The 3S Mini 3SM36 is a DC UPS with selectable output voltages and several adapter options.

  • For this model, Eaton lists 9, 12, 15 or 19 V, the corresponding output currents and four barrel connector adapters.
  • The voltage, output capacity and adapter must be suitable for your specific router. The runtime example in the datasheet is based on a stated load and is not a runtime guarantee for other devices.

APC / Schneider Electric

The Back-UPS Connect CP12036LI is another option to consider when comparing solutions for compatible 12 V network devices.

  • Schneider Electric specifies 12 V DC for this model, along with additional plug tips.
  • The technical specifications alone do not confirm whether a particular version is suitable for your location in Germany and your router. Check the connector type and operating conditions for the exact model.

Joybuy products for running a router in a garden office

Suitable products coming soon.

Frequently asked questions about router UPSs

Will a router UPS keep me online during every power cut?

No. A UPS only powers the devices connected to it. According to the Federal Office of Civil Protection and Disaster Assistance, internet and mobile phone services may also be disrupted during a power cut. Check which devices your local connection needs, and do not rely on the UPS alone to stay connected or make emergency calls.

How do I connect a router and a separate modem?

If both devices need their own power supplies, they must both be connected to battery-backed outputs. A socket-outlet with surge protection only will not be enough. PowerWalker clearly distinguishes between these groups of outputs on the VI 600 MS.

What should I know about the battery and accessories?

Check whether the battery can be replaced on the specific model, and which power supplies or adapters your setup needs. PowerWalker describes the battery in the VI 600 MS as user-replaceable. You cannot assume the same applies to DC models.

What are the important legal points when buying and disposing of a UPS in Germany?

Germany’s Federal Network Agency describes CE marking as the manufacturer’s declaration that a product complies with the applicable EU regulations, rather than an independent quality mark. According to the German Federal Ministry for the Environment, waste electrical and electronic equipment must not be put in household rubbish. Consumers can return used portable batteries free of charge at suitable collection points in shops or local authority facilities. If your UPS has a built-in battery, check how to return the entire appliance when it reaches the end of its life.