Who can benefit from a UPS?

Home offices with a separate modem and router

If your connection uses a separate external fibre ONT and router, both devices need to be taken into account. Deutsche Telekom describes various router configurations for FTTH; which devices you have depends on how your connection is set up.

Users with a single network device

You want to keep a single modem or router running during a power cut without taking up much space, and can check that the device’s voltage, power requirements and connector match those of the DC UPS.

Home offices with other essential devices

You want to power selected work equipment as well as your networking kit. Make sure every device you need is plugged into a battery-backed output and that their combined load is within the UPS’s capacity.

What should you look for when buying?

First, identify the devices that need to run together to keep your connection working. Then compare the outputs and runtime for their combined load.

What you need What to look for Who should pay particular attention?
Keeping the whole connection running List the necessary devices and power supplies for your own connection, and plug them all into battery-backed outputs. According to the manufacturer, four of the PowerWalker VI 600 MS’s eight Schuko sockets are battery-backed. If my connection needs a separate ONT and router, I want to account for both. Around 36 % of consumers prioritise keeping the entire connection running.
Runtime under the combined load Add up the power consumption of all your devices and look for a runtime figure for that load. Eaton gives 40 minutes as an example for an internet gateway drawing 15 W; this figure won’t necessarily apply to other devices. If power cuts vary in length, I want to know how long my devices will run together. Around 29 % of consumers place particular importance on runtime under the actual combined load.
A compatible DC connector Check the voltage, power requirements, plug size and polarity against the device documentation. For the 3S Mini, Eaton specifies 9 V/3 A, 12 V/3 A, 15 V/2,4 A and 19 V/1,89 A, as well as four barrel plug sizes. If I only need to keep one network device running, I want a compact solution that’s an exact electrical match. A suitable power solution for a single device is the main priority for around 21 % of consumers.
Battery replacement and disposal Look up the exact model number to find out whether a replacement battery is available and check the manufacturer’s instructions. The German Environment Agency recommends using battery collection boxes in shops or local authority collection points to dispose of old batteries. If you want to use your UPS for longer and plan to replace the battery, check what’s involved for the specific model. Battery replacement and ongoing costs are particularly important to around 14 % of consumers.

Common buying misconceptions

  • Assuming VA or maximum wattage tells you the runtime

    The rated power doesn’t tell you how long a UPS will keep your devices running. A 2022 comparison by heise online describes how runtime changes non-linearly as the load varies; manufacturers’ runtime figures also apply to specific loads.

    Check the runtime for your actual combined load, rather than relying on a figure given for a different set-up.

  • Assuming every socket is battery-backed

    According to the manufacturer, four of the eight Schuko sockets on the PowerWalker VI 600 MS provide surge protection only.

    Only plug your modem, ONT and router into outputs explicitly marked as battery-backed.

  • Assuming a powered UPS guarantees an internet connection

    A UPS only keeps the devices on your side of the connection powered. It doesn’t automatically protect your provider’s equipment.

    If your connection is important, check how it’s set up and consider having an independent backup connection.

  • Treating old test results as current buying advice

    The comparison published by heise online dates from 2022. Schneider Electric has listed the APC BE400-GR as discontinued since 12 November 2025.

    Check the full model number and the manufacturer’s current status, and separately confirm whether the battery is replaceable.

    Finding a suitable device or replacement battery can take extra time and effort.

Key brands at a glance

Eaton

The 3S Mini 3SM36 is a DC UPS for a single compatible device and may be suitable for a simple network set-up.

  • Eaton says the model has selectable DC outputs and barrel plug adapters.
  • The runtime figure for an internet gateway applies to the stated example load. It won’t automatically power a second device connected separately.

PowerWalker

The VI 600 MS is a Schuko UPS for several devices in a home office.

  • The manufacturer’s datasheet lists 600 VA/360 W, voltage regulation and a user-replaceable battery.
  • Only four of the eight Schuko sockets are battery-backed; these specifications apply to the VI 600 MS.

CyberPower

The BR700ELCD combines Schuko outputs with a status display and voltage regulation.

  • The German manufacturer’s website lists 700 VA/420 W and six minutes at 50 % load.
  • The manufacturer’s figure isn’t a runtime estimate for a low-power modem. Check which outputs are battery-backed.

APC by Schneider Electric

Back-UPS and Easy-UPS models with Schuko sockets have different connection and servicing options.

  • Schneider Electric says the BE650G2-GR has a user-replaceable battery.
  • Schneider Electric says the BE400-GR was discontinued on 12 November 2025; the BV500I-GR is scheduled to be discontinued on 31 December 2026. These details apply only to the specific models.

DIGITUS

A 600 VA/360 W all-in-one UPS featured among the socket UPS models in a 2022 comparison by heise online.

  • The comparison included the product in its selection of socket UPS models at the time.
  • This historical mention doesn’t confirm that the product is still available or that its design hasn’t changed. Check the full model number and the latest product documentation.

Joybuy products

Related products coming soon.

Frequently asked questions

Is it enough to connect just the modem to the UPS?

Only if the other devices needed for your connection have their own power supply or are built into the modem. In an FTTH set-up with a separate ONT and router, both active devices on your side need power; the availability of your provider’s equipment also matters.

How should I connect the devices?

Plug the necessary power supplies into sockets explicitly marked as battery-backed. For a direct DC connection, the electrical specifications and connector must match the specific device. According to the manufacturer, four of the eight sockets on the PowerWalker VI 600 MS provide surge protection only.

When should I replace the battery, and how should I dispose of the old one?

There’s no single replacement interval that applies to every model. Check your device’s manual and the recommended replacement battery. The German Environment Agency recommends taking old batteries to suitable collection boxes in shops or local authority collection points, rather than putting them in household waste.

What should I check in product information for Germany?

For mains-powered devices, the German Federal Network Agency lists checks including a correctly affixed CE mark, an identifiable product and manufacturer, and any required instructions and warnings in German. The CE mark doesn’t guarantee a particular UPS runtime.