Studio with one central NAS
If your main priority is shutting down the NAS safely, check that it can detect when it is running on battery power and initiate a shutdown. Synology and QNAP recommend checking support for your specific NAS model.
For a NAS in a shared studio, choose a UPS with a status connection supported by your specific NAS and enough runtime for an orderly shutdown. Synology and QNAP recommend checking compatibility with the NAS model in question. If users need to keep accessing files during brief power cuts, connect the router or switch to battery-backed outlets too, bearing in mind that extra equipment will reduce the available runtime. Compare the total load with the UPS’s wattage and VA limits, check runtime figures at a similar load, and confirm the outlet configuration and fan operation for the specific model.
If your main priority is shutting down the NAS safely, check that it can detect when it is running on battery power and initiate a shutdown. Synology and QNAP recommend checking support for your specific NAS model.
If users need to keep accessing the NAS during a brief power cut, include the necessary network equipment in your load calculations. Synology and QNAP explain why an adequate power supply matters for NAS operation and shutdown.
Check how each NAS will receive a power-failure notification and whether the network connection will remain available. QNAP notes that a NAS may not receive a UPS notification if its connection to the other device is interrupted.
First decide whether your main priority is shutting down the NAS safely or keeping the studio running during brief power cuts. This will determine the runtime you need and which additional devices to include.
| Requirement | What to check before buying | Who should pay particular attention? |
|---|---|---|
| Automatic shutdown | Compatibility list for your NAS model, supported connection and configurable shutdown response. | If I want my NAS to shut down automatically and safely during a power cut, I’ll check compatibility and signalling first. Around 36% of consumers also prioritise compatibility with NAS shutdown. |
| Runtime under the total load | Power draw of all connected devices, W and VA limits, and runtime figures at a comparable load. | If the NAS and its connected devices need enough power to complete the planned shutdown, I need to check the runtime at my actual load. Around 29% of consumers give sufficient backup time their highest priority. |
| Network and shutdown signals | Router and switch equipment required, battery-backed outlets, and a test to confirm that each affected NAS receives the notification. | If local access or communication between multiple NAS devices needs to remain available, I’ll include the necessary network equipment in my plan. Around 21% of consumers prioritise keeping devices reachable and ensuring shutdown signals work across the studio network. |
| Noise and maintenance | Fan operation in the relevant operating modes, whether the battery can be replaced and which replacement battery is compatible. | If the UPS is near workstations, I’ll consider fan noise in each operating mode and future battery maintenance. Around 14% of consumers particularly value quiet operation and easy maintenance in a studio. |
The VA or wattage rating alone won’t tell you how long the NAS and other devices will run on battery power.
Add up the load of the devices you plan to connect, then compare the runtime figure at a similar load with the time needed to shut them down.
On some models, certain outlets only provide surge protection and won’t keep connected devices running during a power cut.
Make sure you connect the NAS and any essential network equipment to outlets specified as battery-backed in the product datasheet.
Keeping the NAS powered doesn’t guarantee that studio users can still access it or that multiple NAS devices will receive a shutdown notification.
Include only the network equipment needed for access or signalling, and test how all affected NAS devices respond.
A USB port alone doesn’t confirm that your specific NAS model will detect the UPS and respond as required.
Check the compatibility information for both the NAS and UPS, then test the shutdown function once everything is set up.
The Ellipse ECO EL650USBDIN is an example of a compact standby UPS for modest loads and a small number of battery-backed devices.
The VI 800 CSW is a line-interactive UPS with a pure sine wave output and USB-HID.
The CP900EPFCLCD is a line-interactive UPS with a pure sine wave output and six battery-backed Schuko outlets.
No. First check whether your NAS model supports the specific UPS, then configure how the NAS should respond to a power cut. Synology and QNAP recommend checking their compatibility information and testing the shutdown function.
QNAP recommends disconnecting the UPS from mains power after configuration, then checking whether the NAS detects that it is running on battery power and starts the configured shutdown. If you have multiple NAS devices, also check that each one receives the notification.
Check whether the battery is replaceable for the model in question and which replacement battery is compatible. Eaton describes the EL650USBDIN battery as user-replaceable; BlueWalker says the battery in the VI 800 CSW is easy to access and replace. This doesn’t tell you anything about other models.
The Federal Network Agency lists correct CE marking as one of the checks it makes as part of its market surveillance; this is not an endorsement of a UPS’s performance. The German Environment Agency advises against putting used batteries in household waste because of fire and environmental risks. Take them to an appropriate collection point instead.