If you only need to power a compatible router via DC, a compact DC UPS may be suitable. If you also need to power other devices with their own adapters, an AC UPS with enough battery-backed sockets is a more natural choice. First check which devices need to stay on for you to access the internet, then compare the connections, total load and stated runtime. A UPS in your studio won’t automatically power your internet provider’s upstream infrastructure.
Which UPS solutions are right for different studios?
Studios with a DC router
If you only need to power the router, the output voltage, current and connector must match the router’s specifications. Eaton lists selectable DC outputs of 9, 12, 15 or 19 V for the 3S Mini 3SM36; the permitted current depends on the selected voltage.
Studios with several power adapters
If you need to keep other devices with their own power adapters running alongside the router, they must also be connected to battery-backed outputs. Eaton and CyberPower specify battery-backed Schuko outlets on their respective AC UPS models; check the exact outlet configuration and total load.
Studios with a set runtime target
If you need to bridge a specific interruption, or noise and battery replacement matter to you, compare runtime figures at a suitable load with the features of the exact model. Schneider Electric and BlueWalker publish figures for specific models, which won’t necessarily apply to a different load or combination of devices.
What should you consider when choosing?
Compact DC UPS
Suitable if: You only need to power a router with a compatible DC connection.
Bear in mind: DC outputs don’t replace Schuko sockets for additional power adapters.
AC UPS with Schuko outlets
Suitable if: The router and other essential devices each run from their own power adapter.
Bear in mind: Count only outlets explicitly stated to be battery-backed, and check the combined load.
| Buying priority |
What to look for |
Who is this especially important to? |
| Compatible DC connection |
Compare the router’s stated voltage and maximum current with the selected UPS output, and check the barrel connector too. |
If I only want to power the router, its connection must match the UPS’s DC ratings and connector. Around 36% of consumers prioritise compatibility when powering a single router. |
| Powering several internet devices |
List all the essential power adapters, count only battery-backed Schuko outlets, and take the combined load into account. |
If a separate access device needs to keep running alongside the router, I need enough suitable, battery-backed connections. Around 29% of consumers prioritise powering several devices. |
| Runtime at the actual load |
Work out the total power consumption of the connected devices and refer to runtime figures at a load as similar as possible. |
If I need to bridge a specific interruption, I want to be able to estimate the runtime for my set-up. Around 21% of consumers prioritise meeting a set runtime target. |
| Noise and battery maintenance |
Check the noise figures and the conditions they were measured under; for the Eaton 3S550D, the manufacturer states less than 25 dB at a distance of 1 m. Also check that a replacement battery is available for the exact model and review its replacement instructions. |
If the UPS will stay in a shared room, I pay attention to noise and how easy it will be to maintain the battery later. Around 14% of consumers prioritise these points. |
Common selection mistakes
-
Assuming every Schuko socket is battery-backed
Of the Eaton 3S550D’s six Schuko outlets, three are battery-backed; according to Eaton, the other three provide surge protection only.
Connect each essential power adapter to an outlet explicitly stated to be battery-backed.
-
Choosing a mini DC UPS based only on the router brand
Output voltage and permitted current vary depending on the setting. A DC UPS with barrel connectors also can’t power additional adapters via Schuko sockets.
Check the voltage, current requirement and connector of your exact router against the UPS specifications.
-
Using a runtime figure without checking the associated load
Schneider Electric’s runtime curve for the APC Back-UPS BE650G2-GR gives 1 hr 22 mins at 40 W and 28 mins 1 sec at 100 W. These figures are based on specified test conditions, with new, fully charged batteries and a resistive load.
Work out the total load and compare it with runtime figures for a similar load, measured under clear test conditions.
Key brands at a glance
Eaton
The 3S Mini 3SM36 is designed to power a compatible device via DC, while the 3S Gen2 3S550D offers Schuko outlets for power adapters.
- Eaton lists selectable DC outputs of 9, 12, 15 or 19 V for the 3SM36. Three of the 3S550D’s Schuko outlets are battery-backed.
- The 3SM36 has no Schuko outlets; three of the 3S550D’s six Schuko outlets aren’t battery-backed. The stated runtime of up to 80 minutes for a basic router won’t necessarily apply to other router loads or device combinations.
APC by Schneider Electric
The Back-UPS BE650G2-GR is an AC UPS with Schuko outlets and published runtime figures for different loads.
- Schneider Electric lists 650 VA/400 W, eight Schuko sockets and a user-replaceable battery.
- The runtime figures are based on specified test conditions with new, fully charged batteries. Check the outlet configuration and runtime at the load of your devices.
CyberPower
The UT650EG is a line-interactive AC UPS for devices with Schuko power adapters.
- CyberPower lists 650 VA/360 W and three battery-backed Schuko outlets.
- The stated runtime of 16 minutes applies at 90 W and shouldn’t be taken as the runtime for a router at a different load.
PowerWalker
The VI 650 SHL is another line-interactive option for a small studio, particularly if a display and monitoring features matter to you.
- BlueWalker lists an LCD, USB-HID communication and 650 VA/360 W for the VI 650 SHL.
- Runtime figures at half or full load don’t directly show how long a specific router set-up will run. Check that you’re ordering the right plug version.
Suitable products on Joybuy
Consider the Eaton 3S Mini 3SM36 for a compatible DC-powered router; the Eaton 3S Gen2 3S550D, APC Back-UPS BE650G2-GR or CyberPower UT650EG for a router and other devices with power adapters; or the PowerWalker VI 650 SHL if an LCD and monitoring features are important to you. Check outlet configuration, device compatibility and runtime at your expected load before choosing.
Frequently asked questions
How do I connect a router and a separate modem to a UPS?
Connect the devices that need to keep running to outlets explicitly stated to be battery-backed. According to Eaton, three of the Eaton 3S550D’s six Schuko outlets only provide surge protection; also check that the combined load is suitable for the UPS.
Can I convert the VA rating into minutes of runtime?
No. The VA rating alone doesn’t tell you the runtime. Look for runtime figures at a load as similar as possible to yours; Schneider Electric’s curve for the APC Back-UPS BE650G2-GR is based on new, fully charged batteries and specified test conditions.
What should I bear in mind when replacing and disposing of the battery?
Check whether a suitable replacement battery is available for the exact model, and follow the replacement instructions. Germany’s Federal Environment Agency advises that used batteries and rechargeable batteries should be disposed of properly at designated collection or take-back points.
What does the CE marking tell me about a UPS?
A UPS covered by relevant EU rules must carry the CE marking to be placed on the market. The European Union explains that the manufacturer uses it to declare conformity; it isn’t proof of an independent safety assessment.
Will the internet always stay available during a power cut if my router is connected to a UPS?
No. The UPS only powers the devices connected to it and won’t automatically protect your internet provider’s upstream infrastructure. Also check whether your connection needs power for a separate modem or another access device.