Which UPS is right for you?

Server users who need automatic shutdown

If your server runs unattended, a supported status connection and a tested shutdown process are essential. Synology recommends checking the total load and available runtime before choosing a UPS, too.

Server users in a bedroom

If your server and UPS are close to your bed, consider the fan and audible alarms as well as the power supply. ONLINE USV, for example, points out that a fanless model can still sound an alarm when running on battery power.

Users who need services to stay accessible

If you want a service to remain accessible for a while during a power cut, include the server and any essential network devices together when planning the load and runtime. Synology recommends taking the total power consumption of all connected devices into account.

What should you look for when buying?

What to look for What to check Who should pay particular attention?
Automatic shutdown Check that your operating system and software support the UPS status connection; set up and test the shutdown process. If you run your server unattended, you’ll want to avoid it shutting down unexpectedly during a prolonged outage. Around 33% of consumers prioritise a working automatic shutdown.
Power and runtime Compare the total load in watts with the wattage limit and runtime curve for the specific model; include network devices in your calculations. If you want your service to stay accessible for as long as possible, runtime at the actual total load matters more than a single VA rating. Around 27% of consumers focus on how long their devices will run.
Noise and space Check fan and alarm behaviour during normal operation, charging and battery operation, as well as the dimensions. If the UPS is in your bedroom or home office, you’ll want to know what noises it might make in everyday use and during a power cut. Around 20% of consumers prioritise noise levels and space requirements.
Connections and battery replacement Check the output types and which sockets are battery-backed; look into replacement batteries and the warranty terms for the specific model. If you want to connect your existing devices and keep using the UPS for longer, suitable outputs and a straightforward battery replacement are important. Around 20% of consumers focus on connections and future costs.

Common misconceptions when buying a UPS

  • The VA rating tells you how long the server will run

    VA, wattage limit and runtime describe different things. Runtime depends on the connected load; a figure given at half load won’t necessarily apply to a server and router running together.

    Work out the total load in watts and compare it with the runtime stated for the specific model at a similar load, where possible.

    If you want the server to keep running for longer, you may need a compatible external battery system or a different model with a suitable capacity. You’ll also need to allow for the extra space it takes up.

  • A USB connection sets up automatic shutdown

    For shutdown to work, the status data and software must be compatible with your operating system. Connecting the cable alone won’t configure the process.

    Check that your operating system is supported, set up the monitoring software and test the shutdown before relying on it.

  • Every socket provides battery power

    According to Eaton, the Eaton Ellipse PRO ELP650DIN has three Schuko sockets with battery backup; a fourth provides surge protection only.

    Connect your server and any essential network devices to sockets explicitly marked as battery-backed, and check the labels on the specific model.

  • Fanless means silent at night

    A device without a fan can still sound an audible alarm when running on battery power. ONLINE USV notes this behaviour for its YUNTO-Smile models; alarm settings vary by model.

    Check the noise levels for the exact model during normal operation, charging and battery operation, and find out whether the alarm can be configured.

A guide to key UPS brands

Eaton

Eaton describes the Ellipse PRO ELP650DIN as a line-interactive Schuko UPS with USB-HID for lighter loads.

  • For the ELP650DIN, Eaton specifies 650 VA/400 W, three battery-backed Schuko sockets and one additional socket with surge protection. The manufacturer states a noise level of under 25 dB at 1 m.
  • Runtime and suitability for your server depend on the actual load, so check them against your specific combination of devices.

CyberPower

CyberPower lists the CP900EPFCLCD for uses including servers and NAS devices with active PFC.

  • According to CyberPower, the CP900EPFCLCD offers 900 VA/540 W, a pure sine wave when running on battery power, USB software and six battery-backed Schuko sockets.
  • The manufacturer’s stated runtime of seven minutes is based on 50% load. Also check whether the software supports your server’s operating system.

PowerWalker

BlueWalker describes the VI 800 SW and VI 800 CSW as models with different strengths when it comes to operation and battery replacement.

  • For the VI 800 SW, BlueWalker specifies 800 VA/480 W, a pure sine wave, USB-HID and fanless operation.
  • The manufacturer’s stated runtime of five minutes is based on half load; BlueWalker also gives a noise level of under 30 dB for the VI 800 SW. The fan behaviour of the VI 800 CSW should not be assumed to match that of the VI 800 SW.

ONLINE USV

ONLINE USV recommends the YUNTO 800 for small servers and home offices; the ZINTO 800 T is designed for use with an optional runtime extension.

  • For the YUNTO 800, ONLINE USV specifies 800 VA/480 W, USB, fanless operation and a three-year manufacturer’s warranty including the battery. For the ZINTO 800 T, the manufacturer specifies 800 VA/720 W.
  • Additional battery modules for the ZINTO 800 T need space. Check the connections, runtime and dimensions for the specific model.

UPS products at Joybuy

Suitable products coming soon.

Frequently asked questions

Is 800 VA enough for my server?

You can’t tell from the VA rating alone. Work out the total load of all connected devices in watts, compare it with the wattage limit of the specific UPS and check its runtime at a similar load. Synology also recommends taking the available runtime into account.

How does an unattended Linux or NAS server shut down during a power cut?

Connect a UPS status interface supported by your system, set up monitoring or shutdown software, and test the configuration. For Synology products, Synology also recommends checking the compatibility list for your specific NAS.

Should I connect my router to the UPS as well?

If you want your service to remain accessible over your local network during an outage, include the necessary network devices when planning the sockets, wattage load and runtime. A UPS in your room can’t keep the power on outside your accommodation.

What should I consider when replacing and disposing of the battery?

Check whether the manufacturer provides a replacement battery for the specific model, and how to replace it. In Germany, old batteries must not be put in household waste. The Federal Environment Agency lists retail and local authority collection points.

What safety and labelling details should I check before buying?

The Federal Network Agency’s market surveillance checks include CE marking, product identification, manufacturer details, a German-language instruction manual and a declaration of conformity. This does not amount to a blanket approval of any individual listing; check its documentation and, where relevant, the rules at your accommodation.